VAN SLYKE APPARATUS / MANOMETRIC BLOOD GAS APPARTUS / VAN SLYKE BLOOD GAS APPARATUS
Minimum Order Quantity: 1 Piece
Product Brochure
| Material | Stainless Steel |
| Phase | PHARMACY COLLEGE STUDENTS USES |
| Usage/Application | MANOMETRIC BLOOD GAS APPARATUS |
| Container Type | WOODEN FRAME |
| Country of Origin | Made in India |
| VAN SLYKE APPARATUS / VAN SLYKE MANOMETRIC APPARTUS / VAN SLYKE BLOOD GAS APPARATUS | 8500 |
| VAN SLYKE APPARATUS | 8500 |
| PHARMACY COLLEGE STUDENTS USES BLOOD GAS APPARATUS | 8500 |
VAN SLYKE APPARATUS / BLOOD GAS MANOMETRIC APPARTUS / VAN SLYKE BLOOD GAS APPARATUS
The Van Slyke apparatus is a classic laboratory device used for the determination of gases in liquid samples, such as blood or serum. It is particularly well-known for its use in measuring gas content through chemical reactions that release gas into a measurable volume. A Van Slyke apparatus on a wooden stand typically consists of the following components: Glass Parts: Reaction Chamber: A cylindrical glass container where the reaction to release the gas occurs. Manometer: A U-shaped or straight glass tube filled with a liquid (often mercury or water) to measure the pressure or volume of the gas released. Pipettes and Reservoirs: Glass pipettes for precise liquid handling and reservoirs for reagents. Stopcocks and Tubing: For controlling the flow of liquids or gases. Connecting Joints: Ground-glass connections for secure assembly. Wooden Stand: A solid and stable base, often made of varnished or polished hardwood, designed to hold the delicate glass parts securely. Adjustable clamps and mounts to ensure proper alignment of the apparatus and to prevent breakage during experiments.
Additional Information:
- Production Capacity: 100
- Delivery Time: 3 - 5 DAYS
- Packaging Details: IN CARD BOX PACKING
ORSAT Gas Analyzer / Gas Analyzer for Oxygen and CO2 / ORSAT Analyzer for Combustion
Minimum Order Quantity: 1 Piece
Product Brochure
| Country of Origin | Made in India |
| ORSAT Analyzer for Combustion | 13000 |
| ORSAT GAS ANALYSER APPARATUS | 13000 |
| GAS ANALYSER OXYGEN, CARBON DIOXIDE | 13000 |
| ORSAT Gas Analyzer for Laboratories | ORSAT Equipment for Gas Composition |
ORSAT Gas Analyzer / Gas Analyzer for Oxygen and CO2 / ORSAT Analyzer for Combustion / ORSAT Gas Analysis / ORSAT System for Gas Measurement
The ORSAT Gas Analyzer is a laboratory apparatus used to determine the composition of gases in a mixture, especially for measuring the concentration of gases like oxygen (O₂), carbon dioxide (CO₂), and carbon monoxide (CO). The Halden Type refers to a specific design or model variant of the ORSAT apparatus, which is typically constructed in a compact and portable manner. This type of ORSAT analyzer is widely used in laboratory settings to measure the composition of industrial gases, including flue gases, combustion gases, and other gas mixtures.
Features of an ORSAT Gas Analyzer (Halden Type) in a Wooden Box: Wooden Box Housing: The apparatus is usually housed in a sturdy wooden box, providing protection during transport and ensuring that the delicate components are shielded from external damage. The wooden box is typically fitted with compartments to securely store the various parts of the apparatus. Glass Absorption Pipettes: The analyzer contains glass pipettes filled with specific absorbent solutions for each gas to be analyzed (e.g., KOH for CO₂ absorption, pyrogallol for O₂). The design is often compact, with calibrated glass pipettes and a graduated scale to allow for accurate readings. Graduated Measuring Chambers: The measuring chambers are often graduated to precisely measure the volume of gas absorbed by the absorbents. Manual Operation: The Halden type is manually operated, often requiring the user to draw the gas mixture through the apparatus using a pump or a similar device. Each gas is absorbed by its respective absorbent solution, and the change in volume is measured to calculate the concentration. Calibration: The apparatus requires calibration before use to ensure accurate results. This may involve the use of known gas mixtures. Gas Inlet and Outlet: There are inlet and outlet ports through which the gas mixture flows, often controlled by stopcocks. Measuring Scale: A scale is provided to measure the volume of gases before and after absorption, helping determine the percentage of each component. Safety Features: Given the potentially hazardous nature of the gases being analyzed, the apparatus may include safety features, such as valves and vents, to prevent leaks.
Additional Information:
- Production Capacity: 100
- Delivery Time: 3- 5 DAYS
- Packaging Details: IN CARD BOX PACKING
Student Digital Physiograph
Minimum Order Quantity: 1 Piece
Product Brochure
| Screen Size | 4-7" |
| Warranty | 1 Year |
| Product Type | Student Digital Single / Multi Channel Physiograph |
| Usage/Application | Medical uses |
| Model Name/Number | HL -DMCP -668 |
| Brand | H. L. SCIENTIFIC INDUSTRIES PHYSILAB |
| Country of Origin | Made in India |
| PHYSIOLOGY DEPARTMENT PHYSIOGRAPH | 95000 |
| DIGITAL SINGLE CHANNEL PHYSIOGRAPH | 95000 |
| DIGITAL MULTI CHANNEL PHYSIOGRAPH | 95000 |
A Student Digital Physiograph is a device used in educational and research settings to measure and record physiological signals such as:
- Heart rate (ECG)
- Respiration rate
- Blood pressure
- Galvanic skin response (GSR)
- EMG (muscle activity)
✅ Teaching students about physiological processes
✅ Conducting biomedical experiments
✅ Studying human and animal physiological responses
✅ Research in psychology, neuroscience, and physiology
TECHNICAL SPECIFICATIONS
- No of Channels 1 Channel width 100mm (if displayed 1 channel) Noise Level 2 micro Volt (with input shorted with Ground)
- A/D conversion 24 Bit Sampling Rate 500 Hz
- Sensitivity 1, 2, 3, 5, 7.5, 10, 15, 20, 30,50, 75, 100, 200, 300, 500,750 & 1000 µV/cm
- Low Frequency 0.1, 0.3, 0.5, 1, 3, 5, 7 Hz
- (3Db) Filter Hi Frequency Filter 0.1, 0.3, 0.5, 2, 10, 15, 35,70, 99 Hz (3Db) Sweep speed 0.058, 0.937, 1.875, 3.75, 7.515, 30, 60 & 100 mm/sec Notch Filter 50 Hz
- INPUT > 10 M IMPEDANCE CMRR > 120 DB
- Power USB Power
- ·Intended for use in Teaching & Research
- ·Storage of Patient Data for Review
- ·Zoom Facility for detail study of signal ·Simultaneous display on Both TFT & PC together ·
- Online, Offline reformatting of sensitivity, filters, sweep speed & no. of Channels. ·
- Supplies an Extensive Collection of Specialized transducers & accessories ·File compatibility with MS Excel. MATLAB .
- ·Digital Measurement in PC Software measuring time period , 0frequency, amplitude & distance of signal.
CHOICE OF AMPLIFIERS:
1. Bio-Potential - ECG, EEG, EMG, EOG.
2. Strain Gauge - Pressure
3. Pulse
4. Respiration
5. temperature
6. Phonocardiograph
7. EKG (12 Lead)
8. GSR
9. FVC, SVC, MVV TEST (OPTIONAL)
CHOICE OF TRANSDUCERS:
- Pressure Transducer
- Phonocardiograph Transducer
- Pulse Transducer
- Respiration Transducer
- Temperature Transducer
- 3 PIN Junction Box (For EKG, EEG, FMG & FOG recording with Bio - Potential Amplifier
- 5 PIN Junction Box for EKG 12 LEAD recording with EKG Amplifier
Additional Information:
- Production Capacity: 100
- Delivery Time: 3 - 5 DAYS
- Packaging Details: PROPERLY PACKED IN CARD BOX