H. L. Scientific IndustriesH. L. Scientific Industries

Quick Search

Laboratory Research Equipment

Share: FacebookTwitterStumble

We are one of the leading manufacturers & suppliers of Microprocessor UV / VIS Spectrophotometer , Digital pH Meter, Photo Colorimeter, Conductivity Meter, Dissolved Oxygen Meter, Water / Soil Testing Kit, Spectrophoto Meter, Turbidity Meter, TDS . Salinity Meter, Digital Colony Counter, Karl Fisher Titrimeter, Digital Potentiometer, Flame Photometer, Microprocessor Instruments Etc. We are among the very few names in the field of Instrumentation to offer latest technology Instruments for Agriculture, Aqua Culture, Biotechnology, Cement, Chemical, Chemical & Labs, Dairy, Fertilizers, Food & Beverage, Hospitals, Iron & Steel, Industrial Water Disposal, Mineral Water Plant, Metallurgy, Mines & Geology, Pollution Control, Petro Chemical, Plants & Dyes, Pharmaceuticals, Potable Water Plants, Sewage Plants, Textile.



Featured with Latest technology & designed to meet the needs of modern industry. our products are widely used in laboratory . Being one of the leaders for over two decades, we have constantly upgraded our technology and offered excellent after-sales service.




Microprocessor -Visible Spectrophotometer hot

Item Code:HL-21001

Characteristics:

The monochromator with a holographic flashing grating is used. It has the advantage of high wavelength precision, good monochromaticity and low stray light.

Automatic switching of tungsten halogen lamp and deuterium lamp.

A sample compartment for 0.5cm-10cm cells.

Computer control system, precise automatic T/A changeover.

Automatic zero and full scale adjustment.

Direct concentration read-out and concentration factor setting function.

Equipped with RS232 port. Printer can be connected and data can be sent to PC by special software.

Technical Specifications
:

  • Wavelength Range325 - 1000 nm
  • Wavelength Accuracy< 2nm
  • Wavelength Repeatability<1nm
  • Transmittance Accuracy±0.5%
  • Transmittance Repeatability<0.2%
  • Spectrum Bandwidth2nm
  • Stray Light<0.5% (at 360nm, NaN02)
  • Light Current Drift0.5% / 3 min
  • Dark Current Drift0.2% / 3 min
  • Cell Holder Dimensions10 mm
  • Nett Weight13.5 KgsGross Weight27Kgs
Microprocessor -Visible Spectrophotometer

Large View

Send Enquiry


Microprocessor UV-VIS Spectrophotometer hot

Model:HLSI-19191

Technical Specifications:

Display

Graphic LCD (320*240 Dots)

Lamps

Deuterium Lamp & Tungsten Halogen Lamp

Detector

Silicon Photodiode

Dimensions(L*W*H)

630 x 430 x 206 mm

Net Weight

26 Kg

To measure the Absorbance and Transmittance

Quantitative:

Coefficient Method

Standard Curve :
Up to 10 standard samples may be used to establish a curve. 
Four methods for fitting a curve through the calibration points: 
Linear fit, Linear fit through zero, Square fit and cubic fit.

DNA/Protein Test

Concentration and DNA purity and easily calculated:-Absorbance ratios 260 nm / 280 nm with optional subtracted absorbance at 320 nm. DNA concentration=62.9xA260-36.0 x A2B0 Protein concentration=1552xA260-757xA280.

Wavelength Scan

The wavelength scan intervals are 0.1, 0.2, 0.5, 1, 2, 5 nm
High, Medium and Low scan speeds are available. They vary from 100 to 3600 nm/min.
Wavelengths are scanned from high to low so that the instrument waits at high WL and it minimize the degradation of UV sensitive samples.

Kinetics

This mode may be used for time course scanning or reaction rate calculations. Abs vs time graphs is displayed on the screen in real time.

Wait time and measurement time up to 12 hours may be entered with time intervals of 0.5,1,2,5,10,30 seconds and 1 min. Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor.

Microprocessor UV-VIS Spectrophotometer
Send Enquiry


Microprocessor UV-VIS Spectrophotometer(Double Beam)

Model;-HLSI-19191

Microprocessor uv-vis spectrophotometer (double beam) is advanced double beam uv-vis spectrophotometer with more accuracy and flexible requirements. The two detectors are used to measure sample and reference respectively and simultaneously for optimizing measurement accuracy. It has vide wavelength range safisfying requirement of various filed such as biochemical research and industry, pharmaceuticals analysis and production, education, environment protection, food industry etc.

Glass cells

4 no.

Quartz cells

4 nos.

Fuse

2 nos.

Instrument cover

1 no.

Software cd

1 no.

Usb cable

1 no.

Operation manual

1 no.









Technical specifications

Wavelength range

190-1100 nm

Mode

basic/quantitative/wavelength scan/dna protien test/kinetics

Scanning speed

fast / medium / slow

Wavelength accuracy

+0. 1 nm

Bandwidth

1 nm

Wavelength reproducibility

0. 1 nm

Photometric display range

0-200 % t, -0. 3 - 3. 0 a, 0-9999 c

Photometric accuracy

+ 0. 3 % t

Photometric repeatability

+ 0. 2 % t

Stability

0. 001a/h @ 500 nm

Baseline flatness

+ 0. 001 a

Noise

+0. 001a

Stray light

< 0. 05% t @ 220nm, 360 nm)

Data output port

usb

Printer port

parallel port

 

Microprocessor UV-VIS Spectrophotometer(Double Beam)
Send Enquiry


Photo Colorimeters

Item Code:HL-8050

td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }

 

    1 ml. Solution measurements

    Standard glass filters

    Highly stable & accurate


Model

HLSI-19512 Digital Model

HLSI-19513 Digital Model

HLSI-19514 Analog Model

HLSI-19515 Analog Model

Std. Glass Filter

8

5

8

5

Mini Volume

1 ml.

1 ml.

1 ml.

1 ml.

Display

2 1/2 Digit LED

2 1/2 Digit LED

125 x 100 mm
Ammeter

125 x 100 mm
Ammeter

Range

400-700 nm

400-700 nm

400-700 nm

400-700 nm

Output

OD (0 to 1.99)

OD (0 to 1.99)

OD (0 to 1.99) %T (0 to 100)

OD (0 to 1.99) %T (0 to 100)

Resolution

OD : 0.01

OD : 0.01

OD : 0.01 %T-1%

OD : 0.01 %T-1%

Accuracy

0.5% FSI

0.5% FSI

0.5% FSI

0.5% FSI

Detector

Selenium Photocell

Selenium Photocell

Selenium Photocell

Selenium Photocell

Light Source

6.8v, 300mA

6.8v, 300mA

6.8v, 300mA

6.8v, 300mA

Power

230v + 10%

230v + 10%

230v + 10%

230v + 10%

Accessories

Test Tube set of 5, Spare Lamp, Dust Cover, Manual

Filters

8 Filters - 400, 420, 480, 500, 520, 540, 620, 680 nm
5 Filters - 420, 480, 540, 620, 680 nm

 

Photo Colorimeters

Large View

Send Enquiry


Flamephoto Meters

Item Code:HL-8057

Refer attached PDF for detailed technical specifications.
Flamephoto Meters

Large View

Send Enquiry


Microprocessor Spectrophotometer Double Beam hot

Item Code:HL-8062

Refer attached PDF for detailed technical specifications.
Microprocessor Spectrophotometer Double Beam

Large View

Send Enquiry


UV-VIS Spectrophotometer hot

Item Code:HL-210021

Applications

The perfectly designed single beam UV-VIS Spectrophotometer successfully realizes high accuracy and reliable measurement to meet various application requirements. It can be used extensively for qualitative and quantitative analysis in such field as biochemical research and industry, pharmaceutical analysis and production , education ,environmental protection , food industry , clinical examination , santination and antiepidemic etc. The UV-VIS LI-295 series provides excellent application functions without sacrificing accuracy and precision. It's an ideal instrument for various applications.

 SALIENT FEATURES

  • Large LCD Screen
  • Can display and save 50 groups of data, 5 groups per screen.
  • Data can be restored after sudden power cut

  • Auto setting wavelength
  • Tungsten lamp and deuterium lamp can be turned on/off individually to extend lifetime
  • Automatic WL. Calibration and dark current getting.
  • With Wave length Scan Software
  • Technical Specifications

    Wavelength Range 190-1000nm
    Spectral Bandwidth 2 nm
    Optical System Single Beam, Grating 1200 lines/ mm
    Photometric Range -0.3-3.5, 0 to 220% T
    Wavelength Accuracy ± 1 nm
    Wavelength Repeatability 0.3% T
    Wavelength Setting Auto
    Photometric Accuracy ± 0.5% T
    Photometric Repeatability
    0.3% T
    Photometric Range -0.3-3A, 0-200% T
    Stray Light ? 0.3% T
    Stability <0.002A/h (at 500nm,after warming up)
    Detector Silicon photodiode
    Display 128*64 dots LCD
    Standard Cell Holder 4-position 10mm cell changer
    Light Source Tungsten and Deuterium lamp
    Output USB Port & Parallel port (printer)
    Power Requirements
    AC 85- 250V
    Dimensions 420 x 280 x 180 mm
    Weight 12kgs

    >  Design & specification are subject to change without any prior notice.

    >  OEM option available

UV-VIS Spectrophotometer

Large View

Send Enquiry


Karl Fisher Titrimeters

Item Code:HL-8058

  • auto titration control
  • auto zero burette
  • adjustable timer
  • visual & audible alarm

  • model hlsi-19175  hlsi-19176 
    display array of 10 led's in line analog ammeter
    sample size 1 - 50 mg of water 1 - 50 mg of water
    k. F. Dispensing resolution 0. 05 ml. 0. 05 ml.
    indication run add end
    display in auto mode
    run add end
    display in auto mode
    detection current sensing by electronic control current sensing by electronic control
    k. F. Flow highly sensitive solenoid control
    volve for automatic control of k. F. Reagent
    highly sensitive solenoid control
    volve for automatic control of k. F. Reagent
    measuring electrode duel platinum electrode duel platinum electrode
    titration cell air tight 200 ml. Glass vessel air tight 200 ml. Glass vessel
    end point delay 30 seconds 30 seconds
    buzzer yes -
    timer ajustable timer fixed timer
    stirrer variable speed magnetic stirrer
    with on/off control
    variable speed magnetic stirrer
    with on/off control
    burette pressure filling auto zero burette
    with 0. 05 ml. Resolution
    pressure filling auto zero burette
    with 0. 05 ml. Resolution
    power 230v + 10% ac 50hz 230v + 10% ac 50hz
    size 435 x 305 x 150 mm 435 x 305 x 150 mm
    weight 5 kg. (approx. ) 5 kg. (approx. )
    accessories burette(clear glass) 10 ml. , reservoir bottle 500 ml. , rubber bellow for pumping air, titration cell 200 ml, dual platinum electrode, teflon coated magnetic stirring capsule, nozzle, moisture trap with rubber tubing, instruction manual
    Karl Fisher Titrimeters

    Large View

    Send Enquiry


    Microprocessor Uv-Vis Spectrophotometer hot

    Item Code:HL-8061

    td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; } td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }

      Cover 195 to 1000nm

      4 position cuvette holder

      Rs-232c computer interface

      High wavelength precision

      Compact & good looking shape

      Cover 195 to 1000nm

      Highly accurate & stable

    Model               Hlsi - 19185

    Photometric range

    % t:0 to 100%, abs. :0 to 1. 999
    conc. :0 to 1999, k-factor:0 to 1999

    Accuracy

    +0. 005 abs at 1. 0 abs
    +0. 010 abs at 1. 0 abs

    Stray light

    less thn 0. 1% abs at 320 nm

    Readability

    + 1 count

    Data readout

    single line lcd display

    Key board

    4 keys, soft touch membrane type

    Painter interface

    printer interface for any printer

    Serial interface

    rs 232c interface

    Light source

    a) tungsten halogen lamp
    b) deuterium lamp (d2)

    Detector

    wide range silicon photodiode

    Optics

    complete mirror optics with resolution 1200 grooves/mm grating

    Sample holder

    4 position adjustable sample holder

    Power

    230v + 10%, 50 hz. Ac

    Dimensions

    420 x 350 x 240 mm (lxbxh) approx.

    Weight

    10 kg (approx. )

    Technical specifications

    Wavelength

    195 to 1000nm

    Spectral bandwidth

    2 nm

    Accuracy

    + 0. 5 nm

    Repeatability

    + 0. 3 nm

    Resolution

    0. 1 nm

     

    Microprocessor Uv-Vis Spectrophotometer

    Large View

    Send Enquiry


    Electrical Conductivity Meter (Microprocessor Based)

    Item Code:HL-8066

    td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }


      Auto Calibration

      Storage of 100 samples

      Printer attachment facility

      Soft touch membrane keys


     Model                   HLSI-19202

    Specifications:

    Display

    16 x 2 alpha numeric LCD display

    Range

    0.1 uS to 100mS (6 decadic ranges)

    Resolution

    0.1

    Accuracy

    + 1% of F.S. + 1 digit

    Calibration

    Auto / Manual

    Temperature Range

    0 to 100oC

    Cell Conatant

    0.1 to 5.0

    Storage

    Upto 100 samples

    Power

    230V + 50Hz

    Accessories

    Conductivity Cell, Temperature probe, Stand, Clamp, Dust cover, Manual


    Electrical Conductivity Meter (Microprocessor Based)
    Send Enquiry


    Microprocessor Spectrophotometer

    Item Code:HL-8060

    A versatile, rugged, easy to operate and accurate instrument to determine absorbance, transmission and concentration of liquids.
    Microprocessor Spectrophotometer

    Large View

    Send Enquiry


    Auto Colorimeter

    Item Code:HL-8049

    td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }


      Absorbance & %t modes

      Covers 400 to 700nm

      Fast & accurate operations

      Automatic zero calibration

      1ml. Solution measurement

      Standard german glass filters

     

    Model

    hlsi-19150  digital

    Std. Glass filter

    8

    Mini volume

    1 ml.

    Display

    3 digit, bright red 7 segment led

    Range

    400-700 nm

    Output

    od: (0 to 1. 99), %t: 0 to 199

    Resolution

    od : 0. 01, %t : 1%

    Accuracy

    0. 5% fsi

    Detector

    selenium photocell/photodiode

    Light source

    6. 8v, 300ma

    Power

    230v + 10%, 50 hz. Ac

    Dimenstions

    220 x 180 x 125 mm (lxbxh) approx.

    Weight

    2 kg. (approx. )

    Accessories

    set of 5 test tube , spare lamp, dust cover & manual


    Auto Colorimeter

    Large View

    Send Enquiry


    Digital Colony Counters

    Item Code:HL-8064

    td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }


      110mm dia magnifying glass

      Audible confirmation of each count

      Uniform readout from 0. 9999

      Auto marker pen

      Wolffhuegel glass grid with focusing facility

    Model                        hlsi-19200

    Specifications

    Digital display

    4 digit, 999 max. Count(model :lt-37)
    3 digit, 999 max. Count(model:lt-36)

    Dish size

    110 mm

    Magnification

    x 1. 7

    Dimensions

    l 274 x b 320 x h 167 mm (approx. )

    Weight

    3 kgs. (approx. )

    Packaging

    23 cm x 28 cm x 20 cm

    Power

    230v - 10% ac, 50 hz, 40w

    Accessories

    marking pen (1 no. ), magnifier lens (1 no. )



    Digital Colony Counters
    Send Enquiry


    Digital Turbidity Meters

    Item Code:HL-8056

    td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }

     

    Model

    hlsi-19170  

    hlsi-19171 

    Range

    0 to 200 jtu
    0 to 1000 jtu
    2 ranges

    0 to 20. 00 ntu
    0 to 200. 00 ntu
    2 ranges

    Resolution

    1 jtu

    0. 1, 1 ntu

    Accuracy

    +3% fs + 1 digit

    +2% fs + 1 digit

    Sample system

    30 mm clear glass tube

    30 mm clear glass tube

    Light source

    6. 8 v, tungsten lamp

    6. 8 v, tungsten lamp

    Detector

    photodiode

    photodiode

    Display

    3 1/2 digit led display

    3 1/2 digit led display

    Power

    220v+ 10% ac 50 hz

    220v+ 10% ac 50 hz

    Size (lxbxh)

    305 x 305 x 165 mm

    305 x 305 x 165 mm

    Weight

    4 kg (approx. )

    4 kg (approx. )

    Accessories

    test tube set, operation manual & dustcover

    Other models

    analog nephelometer battery cum mains operated also available


    Digital Turbidity Meters

    Large View

    Send Enquiry


    Digtal Tds Meters

    Item Code:HL-8055

    td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }


      Highly Stable and Accurate

      Cell Constant Adjustment Facility

      Available in Lab & Field models

      Temperature Coefficient Correction facility

     

    Model

    HLSI-19167 TDS 
    Table Model


    HLSI-19168
    TDS  Portable Model

    Display

    3 1/2 Digit LED

    3 1/2 Digit LED

    Range

    5 Ranges
    0-1000 ppt Mohs/cm

    2 Ranges
    0-2000 ppm
    0-20 ppt

    Temperature Compensation

    Manual 0-50oC

    -

    Cell Constrant Adjustment

    Adjustable

    Pre Adjustable

    Conductivity Cell

    Platinum DIP

    Platinum DIP

    Measuring Frequency

    1000 Hz

    1000 Hz

    Accuracy

    +1% FSI

    +1% FSI

    Power

    230v + 10%

    1 x 9V Battery

    Dimensions

    76 x 275 x 175 mm

    85 x 28 x 165 mm

    Weight

    2 kg. (Approx.)

    0.8 kg. (Approx.)

    Accessories

    TDS Cell,Operation Manual, Dust Cover


    Digtal Tds Meters

    Large View

    Send Enquiry


    Digital Spectrophotometer

    Item Code:HL-8059

    td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }


      Range 340 to 960 nm

      Direct concentration facility

      Latest solid state ic technology

      Digital display

      Highly stable and accurate

     

    Model

    hlsi-19180 

    hlsi-19181 

    Range

    340 to 960 nm

    340 to 960 nm

    Resolution

    0. 1%t, 0. 001 abs

    0. 1%t, 0. 001 abs

    Output

    %t: 0 t0 100%, abs; 0 to 1. 999, conc; 0 to 1999

    %t: 0 t0 100%, abs; 0 to 1. 999, conc; 0 to 1999

    Detector

    silicon photodiode

    silicon photodiode

    Light source

    6v, 1 amp. Vertical tungsten halogen lamp

    6v, 1 amp. Vertical tungsten halogen lamp

    Monochromater

    600 lines / mm grating

    600 lines / mm grating

    Path length

    10 mm

    10 mm

    Spectral bandwidth

    10 mm

    10 mm

    Wave length resolution

    5 nm

    1 nm

    Wave length accuracy

    2. 5 nm

    1 nm

    Repeatability

    +2 nm

    +1 nm

    Display

    3 1/2 digit led display

    3 1/2 digit led dual display

    Opeating temp.

    5 to 45oc

    5 to 45oc

    Power

    230v+ 10% ac 50 hz

    230v+ 10% ac 50 hz

    Dimensions

    490 x 300 x 165 mm

    490 x 300 x 165 mm

    Weight

    8. 5 kg (approx. )

    8. 5 kg (approx. )

    Accessories

    test tubes(12mm dia) 10 nos


    Digital Spectrophotometer

    Large View

    Send Enquiry


    Digital D.O.Meter

    Item Code:HL-8054

    p { margin-bottom: 0.08in; }td p { margin-bottom: 0in; }

    Model- HLSI 19165  Oxygen dissolved in water, often referred to as DO is a very important parameter of water quality and is an index of physical and biological processes going on in water.

    There are two main sources of dissolved oxygen in water (i) Diffusion of Oxygen from air to water is a physical phenomenon and depends upon solubility of oxygen which, in turn, is influenced by factors like temperature, water movements and salinity etc. Photosynthetic activity is a biological phenomenon carried out by autotrophs (mainly phytoplankton) in water and depends upon autotroph population, light conditions and available gases etc.

    Range    D.O.

    0 to 20.0 ppm

    Resolution    D.O.

    0.1 ppm

    Accuracy    D.O.

    0.1 ppm + 1 count

    Temp. Compensation

    0o C to 50o C Manual

    Compensation    D.O.

    + 3%

    D.O. Sensor type    D.O.

    Amperometric Gold/Silver membrane

    General

    Display

    3 1/2 digit LED display

    Power

    230V A.C. 50 Hz

    Weight

    2 Kg

    Standard Accessories

    DO Electrode

    1 Nos.

    Instruction Manual

    1 Nos.

    D.O. Membranes

    10 Nos.



    Digital D.O.Meter
    Send Enquiry


    Digital Conductivity Meter

    Item Code:HL-8052

    p { margin-bottom: 0.08in; }td p { margin-bottom: 0in; }


      Highly Stable and Accurate

      Cell Constant Adjustment Facility

      Available in Lab & Field models

      Temperature Coefficient Correction facility

     

    Model

    Conductivity 
    HLSI- 19160 
    Table Model

    Conductivity 
    HLSI-19161
    Portable Model

    Display

    3 1/2 Digit LED

    3 1/2 Digit LCD

    Range

    5 Ranges
    0 - 1000 Mohs/cm

    2 Ranges
    2 & 20 Mohs/cm

    Temperature Compensation

    Manual 0-50oC

    -

    Cell Constrant Adjustment

    Adjustable

    Pre Adjustable

    Conductivity Cell

    Platinum DIP

    Platinum DIP

    Measuring Frequency

    1000 Hz

    1000 Hz

    Accuracy

    +1% FSI

    +1% FSI

    Power

    230v + 10%

    1 x 9V Battery

    Dimensions

    76 x 275 x 175 mm

    85 x 28 x 165 mm

    Weight

    2 kg. (Approx.)

    0.8 kg. (Approx.)

    Accessories

    Conductivity Cell,Operation Manual, Dust Cover


    Digital Conductivity Meter
    Send Enquiry


    Digital Automatic Melting Point Apparatus

    Item Code:HL-8065

    p { margin-bottom: 0.08in; }td p { margin-bottom: 0in; }

    Model         hlsi - 19201

      Fully automatic

      Latest technology

      Range upto 350oc

      Highly accurate

      No silicon oil/ heating media required

     

    Specifications:

    Display

    digital 3 1/2 digit, bright led

    Accuracy

    1%

    Operation

    fully automatic

    Dimensions

    l 405 x b 360 x h 235 mm (approx)

    Weight

    5 kg (approx. )

    Power

    230v + 10? , 50hz

    Accessories

    capillary tube - 100 no.
    cleaning tool - 1 no.


    Digital Automatic Melting Point Apparatus
    Send Enquiry


    Digital PH Meters

    Item Code:HL-8051

    td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }

      Highly Stable and Accurate

      Digital Display

      Auto Temperature Compensation

      Auto Polarity & Decimal Indication

    Model

    HLSI-19155
    Auto Temp. Model

    HLSI- 19156
    Table Model

    HLSI- 19157
    Portable Model

    Display

    3 1/2 digit LED

    3 1/2 digit LED

    3 1/2 digit LCD

    Range

    pH

    0 to 14.00

    0 to 14.00

    0 to 14.00

    mV

    0 to + 1999

    0 to + 1999

    -

    Resolution

    pH

    0.01

    0.01

    0.01

    mV

    1

    1

    -

    Accuracy

    pH

    +0.01

    +0.01

    +0.01

    mV

    +1

    +1

    -

    Temperature

    Auto 0 to 100o

    -

    -

    Compensation

    Manual 0 to 100o

    Manual 0 to 100o

    Manual 0 to 100o

    Slope Correction

    80 to 120%

    80 to 120%

    80 to 120%

    Power

    230V + 10%

    230V + 10%

    1 x 9V Battery

    Dimensions

    76 x 275 x 175

    76 x 275 x 175

    85 x 28 x 165

    Accessories

    Combination pH Electrode, Buffer Tablets 4pH & 7pH, Operation Manual, Electrode Stand, Dustcover



    Digital PH Meters
    Send Enquiry


    Portable D.O. Meter hot

    Item Code:HL-19166

    Portable D.O. Meter 

    Features:

    Our gamut of digital dissolved oxygen Meter offered by us is of superior quality and is duly tested ay certain quality parameters. The raw material is sourced from reliable vendors and is carefully manufactured in compliance with international quality norms

    Technical Specifications :

     

    Model

    HL -19166 Potable Model

    Display

    3 1/2 Digital Bright Red LCD

    Range DO TEMP

    0 to 20ppm
    0 to 60oC

    Resolution
    DO / value of TEMP

    0.1ppm
    0.1oC

    Calibration

    Manual

    Accuracy DO

    Temperature Compensation

    Automatic

     

     

     

     

    Portable D.O. Meter
    Send Enquiry



    Contact us
    Mr. Yogesh Goswami / Mr. Yogesh Goswami (CEO)
    Bank Road, Opposite Power House, Mohan Lal Building, 1st Floor
    Ambala, Haryana - 133 001, India
    Telephone:  +(91)-(171)-2643035/ 4009035

    Contact via E-mail

    Contact via Mobile

    Contact via SMS

    Member IndiaMART.com © H. L. Scientific Industries. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited

    Business Enquiry Form


    Add More Products / Services

    (* represents compulsory fields )

    *Describe Your Requirements in Detail
    Please Fill Your Contact Information
    *Contact Person:
    *Email:
    Company:
    Street Address:
    *Country:
    *Telephone:
    Mobile:
    Website:
    *Enter the code:

    Send me a copy of this enquiry