Laboratory Research Equipment |
|
We are one of the leading manufacturers & suppliers of Microprocessor UV / VIS Spectrophotometer , Digital pH Meter, Photo Colorimeter, Conductivity Meter, Dissolved Oxygen Meter, Water / Soil Testing Kit, Spectrophoto Meter, Turbidity Meter, TDS . Salinity Meter, Digital Colony Counter, Karl Fisher Titrimeter, Digital Potentiometer, Flame Photometer, Microprocessor Instruments Etc. We are among the very few names in the field of Instrumentation to offer latest technology Instruments for Agriculture, Aqua Culture, Biotechnology, Cement, Chemical, Chemical & Labs, Dairy, Fertilizers, Food & Beverage, Hospitals, Iron & Steel, Industrial Water Disposal, Mineral Water Plant, Metallurgy, Mines & Geology, Pollution Control, Petro Chemical, Plants & Dyes, Pharmaceuticals, Potable Water Plants, Sewage Plants, Textile.
Featured with Latest technology & designed to meet the needs of modern industry. our products are widely used in laboratory . Being one of the leaders for over two decades, we have constantly upgraded our technology and offered excellent after-sales service.
|
Microprocessor -Visible Spectrophotometer  | | Item Code:HL-21001 Characteristics:
The monochromator with a holographic flashing grating is used. It has the advantage of high wavelength precision, good monochromaticity and low stray light. Automatic switching of tungsten halogen lamp and deuterium lamp. A sample compartment for 0.5cm-10cm cells. Computer control system, precise automatic T/A changeover. Automatic zero and full scale adjustment. Direct concentration read-out and concentration factor setting function. Equipped with RS232 port. Printer can be connected and data can be sent to PC by special software.
Technical Specifications:
- Wavelength Range325 - 1000 nm
- Wavelength Accuracy< 2nm
- Wavelength Repeatability<1nm
- Transmittance Accuracy±0.5%
- Transmittance Repeatability<0.2%
- Spectrum Bandwidth2nm
- Stray Light<0.5% (at 360nm, NaN02)
- Light Current Drift0.5% / 3 min
- Dark Current Drift0.2% / 3 min
- Cell Holder Dimensions10 mm
- Nett Weight13.5 KgsGross Weight27Kgs
| 
 | | Send Enquiry | |
Microprocessor UV-VIS Spectrophotometer  | | Model:HLSI-19191 | Technical Specifications: | | Display | Graphic LCD (320*240 Dots) | | Lamps | Deuterium Lamp & Tungsten Halogen Lamp | | Detector | Silicon Photodiode | | Dimensions(L*W*H) | 630 x 430 x 206 mm | | Net Weight | 26 Kg | | To measure the Absorbance and Transmittance | | Quantitative: | | Coefficient Method | | Standard Curve : Up to 10 standard samples may be used to establish a curve. Four methods for fitting a curve through the calibration points: Linear fit, Linear fit through zero, Square fit and cubic fit. | | DNA/Protein Test | | Concentration and DNA purity and easily calculated:-Absorbance ratios 260 nm / 280 nm with optional subtracted absorbance at 320 nm. DNA concentration=62.9xA260-36.0 x A2B0 Protein concentration=1552xA260-757xA280. | | Wavelength Scan | | The wavelength scan intervals are 0.1, 0.2, 0.5, 1, 2, 5 nm | | High, Medium and Low scan speeds are available. They vary from 100 to 3600 nm/min. | | Wavelengths are scanned from high to low so that the instrument waits at high WL and it minimize the degradation of UV sensitive samples. | | Kinetics | | This mode may be used for time course scanning or reaction rate calculations. Abs vs time graphs is displayed on the screen in real time. Wait time and measurement time up to 12 hours may be entered with time intervals of 0.5,1,2,5,10,30 seconds and 1 min. Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor. | |  | | Send Enquiry | |
Microprocessor UV-VIS Spectrophotometer(Double Beam) | | Model;-HLSI-19191 Microprocessor uv-vis spectrophotometer (double beam) is advanced double beam uv-vis spectrophotometer with more accuracy and flexible requirements. The two detectors are used to measure sample and reference respectively and simultaneously for optimizing measurement accuracy. It has vide wavelength range safisfying requirement of various filed such as biochemical research and industry, pharmaceuticals analysis and production, education, environment protection, food industry etc. | Glass cells | 4 no. | | Quartz cells | 4 nos. | | Fuse | 2 nos. | | Instrument cover | 1 no. | | Software cd | 1 no. | | Usb cable | 1 no. | | Operation manual | 1 no. |
| Technical specifications | | Wavelength range | 190-1100 nm | | Mode | basic/quantitative/wavelength scan/dna protien test/kinetics | | Scanning speed | fast / medium / slow | | Wavelength accuracy | +0. 1 nm | | Bandwidth | 1 nm | | Wavelength reproducibility | 0. 1 nm | | Photometric display range | 0-200 % t, -0. 3 - 3. 0 a, 0-9999 c | | Photometric accuracy | + 0. 3 % t | | Photometric repeatability | + 0. 2 % t | | Stability | 0. 001a/h @ 500 nm | | Baseline flatness | + 0. 001 a | | Noise | +0. 001a | | Stray light | < 0. 05% t @ 220nm, 360 nm) | | Data output port | usb | | Printer port | parallel port | |  | | Send Enquiry | |
Photo Colorimeters | | Item Code:HL-8050 td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }
| Model | HLSI-19512 Digital Model | HLSI-19513 Digital Model | HLSI-19514 Analog Model | HLSI-19515 Analog Model | | Std. Glass Filter | 8 | 5 | 8 | 5 | | Mini Volume | 1 ml. | 1 ml. | 1 ml. | 1 ml. | | Display | 2 1/2 Digit LED | 2 1/2 Digit LED | 125 x 100 mm Ammeter | 125 x 100 mm Ammeter | | Range | 400-700 nm | 400-700 nm | 400-700 nm | 400-700 nm | | Output | OD (0 to 1.99) | OD (0 to 1.99) | OD (0 to 1.99) %T (0 to 100) | OD (0 to 1.99) %T (0 to 100) | | Resolution | OD : 0.01 | OD : 0.01 | OD : 0.01 %T-1% | OD : 0.01 %T-1% | | Accuracy | 0.5% FSI | 0.5% FSI | 0.5% FSI | 0.5% FSI | | Detector | Selenium Photocell | Selenium Photocell | Selenium Photocell | Selenium Photocell | | Light Source | 6.8v, 300mA | 6.8v, 300mA | 6.8v, 300mA | 6.8v, 300mA | | Power | 230v + 10% | 230v + 10% | 230v + 10% | 230v + 10% | | Accessories | Test Tube set of 5, Spare Lamp, Dust Cover, Manual | | Filters | 8 Filters - 400, 420, 480, 500, 520, 540, 620, 680 nm 5 Filters - 420, 480, 540, 620, 680 nm | | 
 | | Send Enquiry | |
Flamephoto Meters | | Item Code:HL-8057 Refer attached PDF for detailed technical specifications. | 
 | | Send Enquiry | |
Microprocessor Spectrophotometer Double Beam  | | Item Code:HL-8062 Refer attached PDF for detailed technical specifications. | 
 | | Send Enquiry | |
UV-VIS Spectrophotometer  | | Item Code:HL-210021 Applications The perfectly designed single beam UV-VIS Spectrophotometer successfully realizes high accuracy and reliable measurement to meet various application requirements. It can be used extensively for qualitative and quantitative analysis in such field as biochemical research and industry, pharmaceutical analysis and production , education ,environmental protection , food industry , clinical examination , santination and antiepidemic etc. The UV-VIS LI-295 series provides excellent application functions without sacrificing accuracy and precision. It's an ideal instrument for various applications. SALIENT FEATURES | 
 | | Send Enquiry | |
Karl Fisher Titrimeters | | Item Code:HL-8058 | auto titration control | | auto zero burette | | adjustable timer | | visual & audible alarm | | model | hlsi-19175 | hlsi-19176 | | display | array of 10 led's in line | analog ammeter | | sample size | 1 - 50 mg of water | 1 - 50 mg of water | | k. F. Dispensing resolution | 0. 05 ml. | 0. 05 ml. | | indication | run add end display in auto mode | run add end display in auto mode | | detection | current sensing by electronic control | current sensing by electronic control | | k. F. Flow | highly sensitive solenoid control volve for automatic control of k. F. Reagent | highly sensitive solenoid control volve for automatic control of k. F. Reagent | | measuring electrode | duel platinum electrode | duel platinum electrode | | titration cell | air tight 200 ml. Glass vessel | air tight 200 ml. Glass vessel | | end point delay | 30 seconds | 30 seconds | | buzzer | yes | - | | timer | ajustable timer | fixed timer | | stirrer | variable speed magnetic stirrer with on/off control | variable speed magnetic stirrer with on/off control | | burette | pressure filling auto zero burette with 0. 05 ml. Resolution | pressure filling auto zero burette with 0. 05 ml. Resolution | | power | 230v + 10% ac 50hz | 230v + 10% ac 50hz | | size | 435 x 305 x 150 mm | 435 x 305 x 150 mm | | weight | 5 kg. (approx. ) | 5 kg. (approx. ) | | accessories | burette(clear glass) 10 ml. , reservoir bottle 500 ml. , rubber bellow for pumping air, titration cell 200 ml, dual platinum electrode, teflon coated magnetic stirring capsule, nozzle, moisture trap with rubber tubing, instruction manual | | 
 | | Send Enquiry | |
Microprocessor Uv-Vis Spectrophotometer  | | Item Code:HL-8061 td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; } td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; } Model Hlsi - 19185 | Photometric range | % t:0 to 100%, abs. :0 to 1. 999 conc. :0 to 1999, k-factor:0 to 1999 | | Accuracy | +0. 005 abs at 1. 0 abs +0. 010 abs at 1. 0 abs | | Stray light | less thn 0. 1% abs at 320 nm | | Readability | + 1 count | | Data readout | single line lcd display | | Key board | 4 keys, soft touch membrane type | | Painter interface | printer interface for any printer | | Serial interface | rs 232c interface | | Light source | a) tungsten halogen lamp b) deuterium lamp (d2) | | Detector | wide range silicon photodiode | | Optics | complete mirror optics with resolution 1200 grooves/mm grating | | Sample holder | 4 position adjustable sample holder | | Power | 230v + 10%, 50 hz. Ac | | Dimensions | 420 x 350 x 240 mm (lxbxh) approx. | | Weight | 10 kg (approx. ) | | Technical specifications | | | Wavelength | 195 to 1000nm | | Spectral bandwidth | 2 nm | | Accuracy | + 0. 5 nm | | Repeatability | + 0. 3 nm | | Resolution | 0. 1 nm | | 
 | | Send Enquiry | |
Electrical Conductivity Meter (Microprocessor Based) | | Item Code:HL-8066 td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }
Model HLSI-19202 | Specifications: | | | Display | 16 x 2 alpha numeric LCD display | | Range | 0.1 uS to 100mS (6 decadic ranges) | | Resolution | 0.1 | | Accuracy | + 1% of F.S. + 1 digit | | Calibration | Auto / Manual | | Temperature Range | 0 to 100oC | | Cell Conatant | 0.1 to 5.0 | | Storage | Upto 100 samples | | Power | 230V + 50Hz | | Accessories | Conductivity Cell, Temperature probe, Stand, Clamp, Dust cover, Manual |
|  | | Send Enquiry | |
Microprocessor Spectrophotometer | | Item Code:HL-8060 A versatile, rugged, easy to operate and accurate instrument to determine absorbance, transmission and concentration of liquids.
| 
 | | Send Enquiry | |
Auto Colorimeter | | Item Code:HL-8049 td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }
| Model | hlsi-19150 digital | | | Std. Glass filter | 8 | | | Mini volume | 1 ml. | | | Display | 3 digit, bright red 7 segment led | | | Range | 400-700 nm | | | Output | od: (0 to 1. 99), %t: 0 to 199 | | | Resolution | od : 0. 01, %t : 1% | | | Accuracy | 0. 5% fsi | | | Detector | selenium photocell/photodiode | | | Light source | 6. 8v, 300ma | | | Power | 230v + 10%, 50 hz. Ac | | | Dimenstions | 220 x 180 x 125 mm (lxbxh) approx. | | | Weight | 2 kg. (approx. ) | | | Accessories | set of 5 test tube , spare lamp, dust cover & manual |
| 
 | | Send Enquiry | |
Digital Colony Counters | | Item Code:HL-8064 td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }
| | | | | | | | | | | Model hlsi-19200 | Specifications | | | Digital display | 4 digit, 999 max. Count(model :lt-37) 3 digit, 999 max. Count(model:lt-36) | | Dish size | 110 mm | | Magnification | x 1. 7 | | Dimensions | l 274 x b 320 x h 167 mm (approx. ) | | Weight | 3 kgs. (approx. ) | | Packaging | 23 cm x 28 cm x 20 cm | | Power | 230v - 10% ac, 50 hz, 40w | | Accessories | marking pen (1 no. ), magnifier lens (1 no. ) |
|
|  | | Send Enquiry | |
Digital Turbidity Meters | | Item Code:HL-8056 td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; } | Model | hlsi-19170 | hlsi-19171 | | Range | 0 to 200 jtu 0 to 1000 jtu 2 ranges | 0 to 20. 00 ntu 0 to 200. 00 ntu 2 ranges | | Resolution | 1 jtu | 0. 1, 1 ntu | | Accuracy | +3% fs + 1 digit | +2% fs + 1 digit | | Sample system | 30 mm clear glass tube | 30 mm clear glass tube | | Light source | 6. 8 v, tungsten lamp | 6. 8 v, tungsten lamp | | Detector | photodiode | photodiode | | Display | 3 1/2 digit led display | 3 1/2 digit led display | | Power | 220v+ 10% ac 50 hz | 220v+ 10% ac 50 hz | | Size (lxbxh) | 305 x 305 x 165 mm | 305 x 305 x 165 mm | | Weight | 4 kg (approx. ) | 4 kg (approx. ) | | Accessories | test tube set, operation manual & dustcover | | Other models | analog nephelometer battery cum mains operated also available |
| 
 | | Send Enquiry | |
Digtal Tds Meters | | Item Code:HL-8055 td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }
| Model | HLSI-19167 TDS Table Model | HLSI-19168 TDS Portable Model | | Display | 3 1/2 Digit LED | 3 1/2 Digit LED | | Range | 5 Ranges 0-1000 ppt Mohs/cm | 2 Ranges 0-2000 ppm 0-20 ppt | | Temperature Compensation | Manual 0-50oC | - | | Cell Constrant Adjustment | Adjustable | Pre Adjustable | | Conductivity Cell | Platinum DIP | Platinum DIP | | Measuring Frequency | 1000 Hz | 1000 Hz | | Accuracy | +1% FSI | +1% FSI | | Power | 230v + 10% | 1 x 9V Battery | | Dimensions | 76 x 275 x 175 mm | 85 x 28 x 165 mm | | Weight | 2 kg. (Approx.) | 0.8 kg. (Approx.) | | Accessories | TDS Cell,Operation Manual, Dust Cover |
| 
 | | Send Enquiry | |
Digital Spectrophotometer | | Item Code:HL-8059 td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }
| Model | hlsi-19180 | hlsi-19181 | | Range | 340 to 960 nm | 340 to 960 nm | | Resolution | 0. 1%t, 0. 001 abs | 0. 1%t, 0. 001 abs | | Output | %t: 0 t0 100%, abs; 0 to 1. 999, conc; 0 to 1999 | %t: 0 t0 100%, abs; 0 to 1. 999, conc; 0 to 1999 | | Detector | silicon photodiode | silicon photodiode | | Light source | 6v, 1 amp. Vertical tungsten halogen lamp | 6v, 1 amp. Vertical tungsten halogen lamp | | Monochromater | 600 lines / mm grating | 600 lines / mm grating | | Path length | 10 mm | 10 mm | | Spectral bandwidth | 10 mm | 10 mm | | Wave length resolution | 5 nm | 1 nm | | Wave length accuracy | 2. 5 nm | 1 nm | | Repeatability | +2 nm | +1 nm | | Display | 3 1/2 digit led display | 3 1/2 digit led dual display | | Opeating temp. | 5 to 45oc | 5 to 45oc | | Power | 230v+ 10% ac 50 hz | 230v+ 10% ac 50 hz | | Dimensions | 490 x 300 x 165 mm | 490 x 300 x 165 mm | | Weight | 8. 5 kg (approx. ) | 8. 5 kg (approx. ) | | Accessories | test tubes(12mm dia) 10 nos |
| 
 | | Send Enquiry | |
Digital D.O.Meter | | Item Code:HL-8054 p { margin-bottom: 0.08in; }td p { margin-bottom: 0in; } Model- HLSI 19165 Oxygen dissolved in water, often referred to as DO is a very important parameter of water quality and is an index of physical and biological processes going on in water. There are two main sources of dissolved oxygen in water (i) Diffusion of Oxygen from air to water is a physical phenomenon and depends upon solubility of oxygen which, in turn, is influenced by factors like temperature, water movements and salinity etc. Photosynthetic activity is a biological phenomenon carried out by autotrophs (mainly phytoplankton) in water and depends upon autotroph population, light conditions and available gases etc. | Range D.O. | 0 to 20.0 ppm | | Resolution D.O. | 0.1 ppm | | Accuracy D.O. | 0.1 ppm + 1 count | | Temp. Compensation | 0o C to 50o C Manual | | Compensation D.O. | + 3% | | D.O. Sensor type D.O. | Amperometric Gold/Silver membrane | | General | | | Display | 3 1/2 digit LED display | | Power | 230V A.C. 50 Hz | | Weight | 2 Kg | | Standard Accessories | | | DO Electrode | 1 Nos. | | Instruction Manual | 1 Nos. | | D.O. Membranes | 10 Nos. |
|  | | Send Enquiry | |
Digital Conductivity Meter | | Item Code:HL-8052 p { margin-bottom: 0.08in; }td p { margin-bottom: 0in; }
| Model | Conductivity HLSI- 19160 Table Model | Conductivity HLSI-19161 Portable Model | | Display | 3 1/2 Digit LED | 3 1/2 Digit LCD | | Range | 5 Ranges 0 - 1000 Mohs/cm | 2 Ranges 2 & 20 Mohs/cm | | Temperature Compensation | Manual 0-50oC | - | | Cell Constrant Adjustment | Adjustable | Pre Adjustable | | Conductivity Cell | Platinum DIP | Platinum DIP | | Measuring Frequency | 1000 Hz | 1000 Hz | | Accuracy | +1% FSI | +1% FSI | | Power | 230v + 10% | 1 x 9V Battery | | Dimensions | 76 x 275 x 175 mm | 85 x 28 x 165 mm | | Weight | 2 kg. (Approx.) | 0.8 kg. (Approx.) | | Accessories | Conductivity Cell,Operation Manual, Dust Cover |
|  | | Send Enquiry | |
Digital Automatic Melting Point Apparatus | | Item Code:HL-8065 p { margin-bottom: 0.08in; }td p { margin-bottom: 0in; } Model hlsi - 19201 | Specifications: | | | Display | digital 3 1/2 digit, bright led | | Accuracy | 1% | | Operation | fully automatic | | Dimensions | l 405 x b 360 x h 235 mm (approx) | | Weight | 5 kg (approx. ) | | Power | 230v + 10? , 50hz | | Accessories | capillary tube - 100 no. cleaning tool - 1 no. |
|  | | Send Enquiry | |
Digital PH Meters | | Item Code:HL-8051 td p { margin-bottom: 0in; }p { margin-bottom: 0.08in; }
| | | | | | | Model | HLSI-19155 Auto Temp. Model | HLSI- 19156 Table Model | HLSI- 19157 Portable Model | | Display | 3 1/2 digit LED | 3 1/2 digit LED | 3 1/2 digit LCD | | Range | pH | 0 to 14.00 | 0 to 14.00 | 0 to 14.00 | | mV | 0 to + 1999 | 0 to + 1999 | - | | Resolution | pH | 0.01 | 0.01 | 0.01 | | mV | 1 | 1 | - | | Accuracy | pH | +0.01 | +0.01 | +0.01 | | mV | +1 | +1 | - | | Temperature | Auto 0 to 100o | - | - | | Compensation | Manual 0 to 100o | Manual 0 to 100o | Manual 0 to 100o | | Slope Correction | 80 to 120% | 80 to 120% | 80 to 120% | | Power | 230V + 10% | 230V + 10% | 1 x 9V Battery | | Dimensions | 76 x 275 x 175 | 76 x 275 x 175 | 85 x 28 x 165 | | Accessories | Combination pH Electrode, Buffer Tablets 4pH & 7pH, Operation Manual, Electrode Stand, Dustcover |
|
|  | | Send Enquiry | |
Portable D.O. Meter  | | Item Code:HL-19166 Portable D.O. Meter Features:
Our gamut of digital dissolved oxygen Meter offered by us is of superior quality and is duly tested ay certain quality parameters. The raw material is sourced from reliable vendors and is carefully manufactured in compliance with international quality norms Technical Specifications : | Model | HL -19166 Potable Model | | | Display | 3 1/2 Digital Bright Red LCD | | | Range DO TEMP | 0 to 20ppm 0 to 60oC | | | Resolution DO / value of TEMP | 0.1ppm 0.1oC | | | Calibration | Manual | | | Accuracy DO | | | | Temperature Compensation | Automatic | | |  | | Send Enquiry | |
|

|